How do I wire a 2nd thermostat for blower only to my electric system for outdoor wood furnace?
electric blowers
November 23, 2009
electric blowers
2 Comments
Tags: Blower, electric, Electric Furnace, furnace, Furnace Thermostat, Heat Pump, only, outdoor, Outdoor Furnace, Outdoor Wood Furnace, system, thermostat, wire, wood
I want the heat pump thermostat to be set on say 65 and the wood furnace to be set on say 70 the wood furnace thermostat only needs to be able to control fan.

gizmoe said:
Nov 23, 09 at 2:49 amWire to R & G on indoor air handler terminals.
You could have a problem with feed back through the other thermostat bringing on the compressor depending on the thermostat you have for the heatpump.
You may need an isolation relay.
DAN Y said:
Nov 23, 09 at 3:16 amUse a line voltage t-stat connected to the hot side of blower motor wire.